NDIR-GFC multigasanalysator MIR 9000e

Biedt superieure metrologische prestaties voor de meting van NOx, SO2, CO, O2, rest-H2O, CO2, CH4 en N2O (broeikasgassen).
Nieuw: Geautomatiseerde driftcontrole-optieNDIR-GFC Multi-Gas Analyzer MIR 9000e
Eco-ontworpen, ultracompact, slim en verbonden instrument, de MIR 9000e is uw volgende tool om verbrandingsgas van ketels of gas van verschillende industriële ovens en procestoepassingen te meten.

Het biedt superieure metrologische prestaties voor de gelijktijdige multi-gasmeting van: NOx, SO2, CO, O2, rest-H2O, CO2, CH4 en N2O (broeikasgassen).

Nieuw: Geautomatiseerde driftcontrole-optie

Kenmerken en voordelen
Nieuw: Geautomatiseerde driftcontrolefunctie
Geautomatiseerde kwaliteitscontrole van de on-site gegevens dankzij zero driftcontrole en kalibratiecontrolepunt. Deze functie kan worden aangeschaft met de analyzer, of later, wanneer de analyzer in werking is. In dit geval wordt deze op afstand geactiveerd door onze klantenservice; Deze optie is gecertificeerd door TÜV voor QAL3 (Quality Assurance Level 3, verplicht in de EU) volgens de normen EN 14181 / EN 15267-3 (in afwachting van officiële publicatie op QAL1.de).
Ingebouwde Shewhart-controlekaart voor statistische procescontrole (SPC); Mogelijkheid om te werken in concentratie of in %. Programmering in uren/dag/maand.
Drift standaardmelding beschikbaar (digitale uitvoer op de analyzer of verzoek van DAHS).
  • Superieure metrologische prestaties voor de gelijktijdige meting van meerdere gassen: NOx, SO2, CO, O2, rest-H2O, CO2, CH4 en N2O (broeikasgassen)
  • Milieuvriendelijke en kostenbesparende analysator, met een extreem laag stroomverbruik
  • Geen perslucht nodig (bij gebruik van een gaskoeler)
  • Ongevoelig voor T°-variaties in het bereik van +5° tot +40°C (geen airconditioning nodig)
  • Compatibel met elk type droogtechnologie (gaskoeler, permeatie, verdunning...)
  • Baanbrekend mechanisch ontwerp voor gewichts- en energiebesparing en thermische isolatie en betrouwbaarheid
  • Proactieve, gebruiksvriendelijke communicatie op afstand
  • Slimme analysator met AMS-besturingsfuncties: geïntegreerde bemonsteringsregeling, automatische nul- en spangasinjectie, externe pompregeling, weergave van systeemalarmen...
  • Zeer nauwkeurig, uitstekende stabiliteit, zuinig, eenvoudig en minder onderhoud
Belangrijkste toepassingen
  • Industriële boilers en ovens
  • Energieopwekking en verbranding
  • Gasturbines
  • Chemische en petrochemische fabrieken
  • Procesgasbewaking…
  • Chemicaliën (bijv. TiO2 / Coatingpoeder)
  • Energieopwekkingscentrale (bijv. steenkool/biomassa)
Measuring Ranges
NOx as NO2
(after NOx converter)
0 – 100* / 1,500* / 5,000 mg/m3
SO2 0 – 75* / 1,500* / 7,500 mg/m3
CO 0 – 75* / 3,000* / 12,500 mg/m3
O2 0 – 25%
Residual H2O 0 – 2%
CO2 0 – 20 / 0 – 30 %
CH4 0 – 50* / 200* / 1,000 mg/m3
N2O 0 – 50* / 200* / 1,000 mg/m3

*QAL1 range.

Technical Specifications
QAL1 to EN 15267-3 certified YES
US EPA compliance YES
Sampling technology Cold/Dry Extraction (SEC Box or gas cooler)
Sample transfert non heated polytube / heated sampling line
Back flush function YES
Span injection YES on analyser or at sample point
Built-In O2 option YES
Serial link communication RS232 / RS422
Other Communication Modbus TCP, Modbus RTU (dongle),
UDP protocol Ethernet RJ45, Wifi, USB 2.0 / 3.0
Analogue OUTPUTS 4 to 8 analogue outputs (0-1 V, 0-10 V, 0-20 mA, 4-20 mA)
6 to 12 relay outputs
Analogue INPUTS 4 to 8 logical inputs
Dimensions (mm) 19’’ rack, 3U; 483x330x133 mm (WxDxH)
Infraroodanalysatoren maken het mogelijk om een ​​verscheidenheid aan gascomponenten met hoge gevoeligheid te meten, een technologie die ENVEA al vele jaren gebruikt en die voortdurend is doorontwikkeld met zijn bekende MIR 9000-generatie gasanalysatoren. De MIR 9000e is een nieuwe generatie gasmonitoren die profiteert van een unieke eco-design-expertise. De MIR 9000e kan tot 8 componenten meten, afhankelijk van uw selectie. NOx, SO2, CO, CH4 en N2O worden gemeten met de Non-Dispersive Infrared Gas Filter Correlation-methode (NDIR-GFC), terwijl O2 wordt gemeten met een ingebouwde zirkonia-sensor (of paramagnetische cel op aanvraag). De gasmonitor is eco-ontworpen en maakt gebruik van de meest recente optische en elektronische technologieën die een grotere precisie en robuustheid bieden, terwijl er slechts beperkt onderhoud nodig is.
Complete systemen zouden bestaan ​​uit:
  • Sampling- en conditioneringssysteem
  • Sampling-lijnen
  • NOx-converter
  • Data-acquisitie- en beheersysteem

Goedkeuringen en certificeringen
De multigasmonitor voldoet aan de hoogste internationale en Europese normen, zoals EN 15267 en is getest en gecertificeerd volgens de "TUV Approved"-richtlijnen van de TÜV Rheinland Group.
QAL 1 gecertificeerd door TÜV volgens EN 15267-1 (2009), EN 15267i2 (2009), EN 15267-3 (2007) en EN 14181 (2014). Download het TÜV-certificaat: 0000074621 00

Documentatie

envea_mir_9000e_ndir-gfc-multi-gas-analyzer-process-emissions_en envea_mir_9000e_ndir-gfc-multi-gas-analyzer-process-emissions_en
ENVEA_Process_Catalogue_EN ENVEA_Process_Catalogue_EN
envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en

Ankersmid engineert, levert en pleegt service aan analyse apparatuur, tot complete CEM systemen en proces systemen in bijbehorende analysehuizen. Zij worden gebruikt in de industriële procestechniek, laboratoria, luchtmacht, staltechnieken en biogas installaties

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group